Sunday, December 1, 2019

Ventilation Essays - Intensive Care Medicine, Respiratory Therapy

Ventilation Ventilation is the mechanical process whereby air is taken into and out of the lungs. Situations in which a patient might require venitlatory support range from apnea to patients experiencing depressed respiratory function. If the patient's rate of breathing decreases significantly it can lead to hypercarbia, hypoxia, a lowered pH level and a decrease in respiratory minute volume. This can result in cardiac or respiratory arrest if it isn't corrected. Expired air ventilation has been accepted as the technique of choice since the late 1950s. It has been shown to be an effective practice for both professionals and lay persons including young children over 5 years of age. Ventilation using the expired air of the rescuer can be applied to the mouth or nose of the adult victim and to the mouth and nose of the infant. Mouth-to-Mouth ventilation and Mouth-to-Nose ventilation can provide effective ventilatory support to a patient. A major advantage of these methods of ventilation is that no equipment is required to effectively offer ventilatory support to the patient. However, the disadvantage of these methods of ventilatory support are that both methods only offer a limited oxygen supply due to the fact that oxygen expired from the rescuer will only contain 17 percent oxygen. Mouth-to-Mask Ventilation or Pocket Mask Ventilation A clear, plastic, molded facemask similar to that used in anesthesia may be used to provide mouth to mask ventilation. A unidirectional valve diverts the patient's expired air away from the rescuer and traps any macroscopic particles emerging from the patient. This valve improves the aesthetics and reduces risk of cross infection. The mouth to mask method is a two handed technique which produces a better seal than that obtained during single-person bag-valve-mask ventilation. As with mouth-to-mouth ventilation it is possible to generate high tidal volumes, high airway pressures and increase the risk of gastric inflation. The addition of a port for the administration of supplemental oxygen increases the inspired oxygen concentration. A variety of pocket masks are available. Some of these masks are disposed of after the first use while others may be used many times. Most are small and compact enough to fit in a pocket and may be carried with the paramedic. The pocket mask allows an oxy gen flow rate of 10 liters per minute. This rate combined with mouth-to-mouth breathing of the rescuer yields an inspired oxygen rate of about 50 percent. This is a significantly higher oxygen concentration level than delivered through the mouth-to-mouth or mouth-to-nose method. Inexpensive protection devices made from a piece of plastic film with a valvular orifice to cover the mouth and nose will provide protection and reduce aesthetic worries of direct contact with patient's vomitus, saliva, sputum or blood. The main disadvantage is that the film device requires repositioning for each sequence of breaths. In the community the bystander is likely to be a relative, friend or colleague of the victim and resuscitative efforts should not be deterred by the unavailability of a protective device, as the risk is very small. Bag-Valve Ventilation The self-inflating bag can be connected to either a facemask, a tracheal tube, a laryngeal mask, or a Combitube. The bag consists of an oblong, self-inflating silicone or rubber bag; two one-way valves, and a transparent facemask. They are available in sizes for babies, children and adults. The bag-valve device allows room air or oxygen to be delivered to the patient. When used on its own the bag-valve-mask will allow ventilation of the patient with ambient air (21% oxygen). This can be increased to around 50% by attaching an oxygen supply at 5-6 Lmin-1 directly to the bag next to the air inlet valve. Normally, however, a reservoir bag should be attached, which with oxygen flows of 8-10 Lmin-1, will provide inspired oxygen concentrations of 90%. Certain ideal criteria have been laid down for bag-valve-mask devices used in resuscitation The requirements recommended include: The bag material should be transparent and convey a satisfactory feel. It should not absorb anesthetic or noxious gases and should possess sufficient recoil to draw in gases from a reservoir or a draw over anesthesia circuit. Both inlet and outlet valves should be of robust construction, competent to prevent rebreathing or leaks, incapable of malfunction or

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.